Cold spray zinc · heavy-duty coatings

Galvanizing protectionwithout the galvanizing plant

Cold spray zinc deposits a zinc layer of over 96% at ambient temperature. Apply it on site, on structures that are already erected, with a brush, roller or spray gun — no thermal deformation, no transport, no plant outage.

96% Zn in dry film
25years design life
Sa 2.5surface prep only
0thermal deformation

01 — Cold Spray Zinc

Why cold spray zinc replaces hot-dip galvanizing

Hot-dip galvanizing needs the part to travel to a plant, be dipped at 450 °C, and come back. Cold spray zinc is applied where the steel already is.

Cold spray zinc (ZD96-1)Hot-dip galvanizing
Zinc content≥96% metallic zinc in dry film≥98% (molten bath)
Application temperatureAmbient (5–40 °C)450 °C molten zinc
Thermal deformationNoneRisk on thin / long members
Where appliedOn site, on erected structuresMust travel to a plant
Plant outageNoneDismantling and transport
Max component sizeUnlimitedLimited by bath size
Surface repairRepairable in place by brush or aerosolDamaged coating bares the steel
Recoat / topcoatAccepts full paint systemRequires specialised adhesion primer
Design life25 years (manufacturer figure)25–50 years depending on class
ColourZinc grey, or overcoat any RALZinc grey only

Technical data →

Technical note · 10 min read

Cold galvanizing vs hot-dip: the comparison most articles get wrong

Zinc mass per square metre, not thickness in microns, is what decides whether cold spray can replace hot-dip. The arithmetic, the boundary cases, and where the substitution fails.

Read the note →

03 — Projects

Projects

Cold spray zinc in service on bridges, wind towers, power infrastructure, port machinery and tanks.

View all →

04 — Ready stock

Stock in hand, packed the way it ships

Photographs taken in the warehouse we ship from in Shanghai — not renders. What you see is what gets loaded: pails strapped to pallets, a UN 1263 Class 3 label on every drum, racked stock waiting for the container booking.

Picking aisle, Shanghai warehouse — Pallet positions either side of the marked walkway — pails in front, export cartons stacked behind.
Picking aisle, Shanghai warehousePallet positions either side of the marked walkway — pails in front, export cartons stacked behind.
Palletised and stretch-wrapped — Pails filmed as one pallet before loading — no re-packing at the port.
Palletised and stretch-wrappedPails filmed as one pallet before loading — no re-packing at the port.
Label detail, 20 L pail — Batch number, production date and the UN 1263 Class 3 marking are on the pail itself, not only on the shipping documents.
Label detail, 20 L pailBatch number, production date and the UN 1263 Class 3 marking are on the pail itself, not only on the shipping documents.

Photographs taken at the warehouse in Shanghai. Marks and brand names on packaging belong to their respective owners.

05 — FAQ

Frequently asked questions

Can cold spray zinc replace hot-dip galvanizing?

For most C3 and C4 structures, yes. The dry film contains over 96% metallic zinc and protects steel the same way a galvanized coating does — the surrounding zinc becomes the anode when the coating is scratched to the steel. Hot-dip galvanizing still wins where the part fits a bath and the 25-year-plus life in C5 immersion is specified; cold spray zinc is the practical answer for large welded structures, repairs on site and anything that cannot be transported.

What surface preparation does it need?

Sa 2.5 to ISO 8501-1 with an angular profile of Rz 40–75 µm, and priming within four hours of blasting. The zinc bonds by mechanical and electrical contact, so a surface that is only wire-brushed leaves the sacrificial circuit open and the coating fails early. In repair work on existing galvanized steel, degrease, wash off soluble zinc salts with high-pressure fresh water, then abrade local rust before application.

How long does it last, and how many coats are needed?

The ZD96-1 system is specified for a 25-year design life in C3–C4 within a full coating system. In C3 environments the zinc can be used alone as a single coat at 60–80 µm; from C4 upward it is the base of a system — zinc, then an intermediate or sealer such as ZB18-12, then a polyurethane topcoat such as ZD6430 for colour and gloss retention.

Is it a dangerous good for shipping?

Yes. Solvent-borne grades ship as dangerous goods under UN transport regulations. We classify each SKU, issue the MSDS in the buyer's language and arrange the export packaging certificate needed for the booking, then ship from Shanghai or Ningbo on FOB, CFR, CIF or DAP terms.

How is it priced, and what is the minimum order?

Priced per litre delivered, not per drum list price, because the consumption per square metre is what drives project cost. Send the structure, the steel condition, the area and the corrosivity category and you get back a system, film builds and a delivered price. Orders start from one pallet for stock items; made-to-order batches follow the factory schedule.

Not sure which grade fits your environment?

Send us the structure, the steel condition and the corrosivity category (C2 to CX). We reply with a coating system, film builds and a delivered price.

Request a quote